eDMX Pass-Through Buses
An eDMX pass-through file should include the following required data:
-
Controller - the number of the controller on which to create the bus
-
Bus number - the unique number used to refer to the bus
-
Protocol - the eDMX source protocol
-
Bus universe - the eDMX source universe
NOTE: These columns are required to import the pass-through bus.
The following columns are optional, and if not provided, the default will be used.
-
Bus name - A name for the pass-through bus
The following can be set for any columns.
-
Ignore - use if there is data in the text file which should be ignored
Example
The data below will import 4 pass-through buses using Art-Net universes 1000-1003 and add them to various groups.
Controller number, Bus number, Bus name, Bus protocol, Bus universe
1, 1, Bus 1, artnet, 1000
1, 2, Bus 2, artnet, 1001
1, 3, My Third Bus, artnet, 1002
1, 4, My Fourth Bus, artnet, 1003